The Camera function is not interfaced as indicated. Hello, please can you help me, how should I configure PCI 1409 to acquire whole image throught two inputs. The National Instruments PXI-1409 (Part number: 778336-01) IMAQ Device supports four broadly useful control lines that are configurable to create exact timing signals for controlling camera acquisition. Connect the power supply cord to the power supply. (canopus, AD. In Windows 11, Windows 10 & Windows 8. Re: PCI-1409ボードのドライバーを入手するには. Set the Frame timeout and Action inputs appropriately based on your intended behavior. Industries. The NI 1409 Series works with the highest quality Original: PDF 10-bit 2000/NT/XP/Me/9x PCI 1409 IMAQ-A6822 PXI-1409 NI PXI-1409 PCI-1409 PXI 1409 IMAQ-A6804 RS170 RS170 Module linescan IMAQ PXI-1409: EMM5075VU. This condo was built in 1995 and last sold on for. National Instruments PCI-1409 NI IMAQ Video Frame Grabber Card. icd (3 kb) Camera File for use with NI-IMAQ 2. Hi C. NI-DAQmx. bmp therefore i save as lossless compressed . Top Results (5) Part ECAD Model Manufacturer. Also, although current clinical data suggest a benefit for. Now, we want to replace the desktop with a Laptop computer. My video image has a noise band which moves from below to top in the frame. The NI PCI-1409 enables users to acquire images from variable-scan and line-scan devices with pixel clocks ranging from 2 MHz to 40 MHz. You may receive a partial or no refund on used, damaged or materially. All Manuals. LabView 8. 2 Gen2 Type-C®, front USB 3. Anadaptor(PN187797-0R3)isNational Instruments PCI-1409 Image Acquisition Module. Select the Driver tab. Authors Khalil Ibrahim 1 , Rohan Shah 2 , Rakesh. NI PCI-1409 NI IMAQ Video Frame Grabber Card Used . NI FlexMotion PCI-1744 stage controller controls the Deadal motorized stage to follow the animal, and receives the stage position information. PCI Serial Port . 1 using Vision 6 i realise i have to set up as 16 bit. Hi you should also install IMAQ drivers: the PCI-1409 Using the Image Acquisition Toolbox, create the video input object to record video and set up the parameters for acquisition. 7,533 7. Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers. 1 USB 3. Troponin-I was measured post-PCI using a high-sensitivity troponin-I assay (hs-TnI). PCI-1409 PLCs/Machine Control from NATIONAL INSTRUMENTS In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - DISCONTINUED BY. After you have installed all the software, and then the drivers, you should shut down the computer and physically install the PCI board. NI PXI-1409 User's Manual - Artisan Scientific. Machine Vision products include vision systems, smart cameras, frame grabbers, and vision interfaces designed for a wide range of applications, such as assembly verification, object tracking and vision-guided robotics. How to download and install Multi-IO Adapter PCI Multi-I/O Adapter driver (driver id 2148458). Knight of NI. 0. Hello, I have a PCI-1410 Frame Grabber. File Size: 4. Is anyone has experience t. Top Results (5) Part ECAD Model Manufacturer Description. 1, 8, or 7. The interface logic ensures that the NI 1409 meets the loading,. 0_KHW7P_Setup_ZPE. Make sure to keep the Python indentation (four spaces) and type task. EN. Set the Line Number to be the DAQ trigger line on which the trigger will be output. This warranty includes parts and labor. exe. 1055/s-0038-1666862. 5 or later請教PCI-1409 與 TELI CCD接線問題,我以測試CCD再BNC 模式時再Measurement & Automation ,SNAP可看到IMAGE 但將W1 jumper 移除使用68-pin VHDICThis package installs an updated version of the Microsoft Windows 7 64-bit device driver for the following Sunix PCI Parallel Port cards. : pci-1410는 더이상 비표준 카메라로 부터 영상을 얻기위해 외부 픽셀클럭을 필요로 하지 않는 새 pll을 가지고 있습니다. Select the Driver tab. The center shall make accessible to the National Missing and Unidentified Persons System specific. 4-channel, Nonstandard Analog Image PXI Frame Grabber Module—The PXI-1409 has 10-bit digitization for cameras and sensors that offer 60 dB dynamic range. My dream is the frame reset mode of JAI CV-M10RS CCIR camera operation under the IMAQ PCI 1409 frame grabber. The NI 1409 devices work , ! device that offers comparable or greater resolution. Morphine delays and attenuates ticagrelor exposure. Ray. The vision drivers should still have drivers for this card. W. Objective: To evaluate the prevalence and outcomes of same-day discharge among older patients undergoing. Use the NI-IMAQ function IMAQ Configure Trigger3. pci-1409とアナログカメラを使用して画像集録を行なっています。 集録環境の問題で1409とカメラとを接続しているbncケーブルが画像集録中に切断される可能性があります。 切断が起こった場合にはエラーが発生すると思っていたのですが、実際に切断されてもプログラムは停止せずに空の画像を. The PCI-1409 features 10 Mb of onboard. In LabVIEW 6. The PCI-1409 features 10 Mb of onboard memory. Device or core chip manufacturer is SUNIX Co. Click the Update Driver button and follow the instructions. I developed an application using LV 6. How to download and install SUNIX Co. Set the Line Number to be the DAQ trigger line on which the trigger will be output. 0 USB 3. Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers. PCI-GPIB Hardware Characteristics Characteristic Specification Dimensions 13. Favorite Dear for Windows (フェイバリットディア フォー ウィンドウズ) NEC Interchannel (エヌイーシーインターチャネル) Manual PDF Scans (説明書 PDF スキャン) Windows95/98/2000. I have problem when I trigger the acquisition ; I'm not able to synchronise the camera and the acquisition. What you Need to Get Started You need the following items to set up and use NI 1409: NI 1409. hardware configurations. I need to assemble this divided imag. However my PC/win200 with Labview-7& Imaq don't offer an *. National Instruments will, at its optio n, repair or replace equipmen t that proves to be defective during the warranty period. Sunix Parallel Port Controller SUN1999 for Windows 10 (64-bit) - ThinkStationSolved: Hi- Has anyone successfully used the Sony XC-HR90 and the PCI-1410 frame grabber? If so, did you have to use the IMAQ A8014 cable? I have. High-quality monochrome image acquisition boards for pci, pxi, and compactpci bus (55 pages). Hello all, Anybody can help my vision card which is PCI-1409, I don't know what happenned, as I plug the card on the PC, PC can't boot up anymore, hasn't any response, and after I pull that card out, PC is well boot up, then I replace the other piece of PCI-1409, PC is well boot up too,. 1 NI-DAQmx 7. Search. The PC's OS is Windows XP (Microsoft Corp. Manufacturer. The camera has square pixels, so this should not be the problem. vi before IMAQ Grab Setup. High sensitivity - 1/3 IT HAD CCD. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed; Permalink; Print; Report to a Moderator;NI-Serial 3. NI Employee (retired) 09-29-2009 04:58 AM. Unfortunately, many good cameras do not have a genlock input. 11,14 Consistent with the previous results, the current study demonstrated that the risk of MACE was 2-fold higher in patients with. We are interfacing Jai CV-A1 CCD with NI1409: While trying to grab with Measurment & Autimation, it is showing : "Aquisition Error: can't lockThis is not a question but an answer to those who want to capture a VGA like (640x480 60Hz) image from a computer or an automate with a NI PCI 1409. The NI PXI/PCI-1409 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. Simplified and flexible trigger. Missing subVI in Actimetrics FreezeFrame2 software, PCI-1409 card, Windows 7 PLab. 3. . 5 version. If not otherwise indicated, eye movements were tracked at 5 frames/s throughout the study. IMAQ PCI/PXI-1409 User Manual November 2000 Edition Part Number 322811A-01. 4-channel, Nonstandard Analog Image PXI Frame Grabber Module—The PXI-1409 has 10-bit digitization for cameras and sensors that offer 60 dB dynamic range. Try downloading this and overwriting the camera file that exists in C:Program FilesNational InstrumentsNI-IMAQData. The PCI interface, implemented with the National Instruments MITE ASIC, can transfer data at a maximum sustained rate of 100 Mbytes/s in master mode to maximize the use of the available bandwidth. When I connect it to the 1409 I get an image using the generic 60Hz progressive scan camera file. 9393. The PCI/PXI-1409/1410 is able to acquire still images from an RGB camera. Genlocked: (IMAQ PCI/PXI 1408, IMAQ PCI/PXI 1409) Use this mode to connect multiple cameras to one image acquisition device using a method called Genlocking, which ensures that the cameras start sending their frames simultaneously. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100 Worldwide OfficesPCI-1409. However, it ceases to acquire the image (CCIR 25fps) telling me it can't capture that much video data and asking me to reduce the image. Chan MY, Sun JL,. Get the latest official SUNIX 4-Port Serial Card multifunction adapter drivers for Windows 11, 10, 8. 6. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Complete the following instructions to install the PCI-1409. We have 1 NI IMAQ PCI-1409 manual available for free PDF download: User Manual . 7 days NI-Serial 3. The new XC-ES50. 2, 8. $2,250. 2002/95/EC 2011/65/EU. viが特殊な映像出力方法をおこなっているために起こる現象で、PCI-1409のMAXのプロパティでPCI-1409のデフォルト設定であるイメージ取得. Update drivers using the largest database. When I recently installed the later Imaq driver 3. 8%We used NI vision (IMAQ PCI-1409), motion controller (PCI-7344), and DAQ (PCI-6025E) cards for this MPVIEW. Instruments from Apex Waves, LLC at used-line. 问题: pci-1410和pci-1409有什么区别,能否使用pci-1410替换pci-1409? 解答: pci-1410是高质量,多通道,模拟视频采集卡. It doesn't allow me to save as . 0. Click on Update driver. Real-time image acquisition and display are attained with LabVIEW software. Then open MAX and be sure that the camera file selected is still the one for the JAI CV. 2 slots, PCIe® 5. The new XC-ES50/30/CE series of video cameras are the smallest and lightest, one piece 1/2" and 1/3" analog B/W video cameras in Sony's line up to date. All cables and accessories for the PCI-1409 are compatible with the PCI-1410. How to download and install Manufacturer 2 ports Parallel Board driver (driver id 1818928). Tags (4) Tags: Archived. Get the best deals for ni pci-1409 at eBay. 0. The NI PXI/PCI-1409 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. C, 24-Jun-13 2 , 25 °C, unless otherwise noted) Note â ¢ Dots and squares represent measured data. The National Instruments PCI-1409/PXI-1409 image acquisition module offers quick and easy configuration when high-resolution, measurement-quality images from standard and nonstandard cameras and sensors are needed. High-Quality Monochrome Image Acquisition Boards for PCI, PXI, and CompactPCI Bus. 38 lb, and measures 3. 8086:0152:103c:3396 ». 0kb) Camera File for use with NI-IMAQ 2. bmp therefore i save as lossless compressed . 1. scotia673. 3 IMAQ Vision RT 7. NATIONAL INSTRUMENTS. The PCI-1409 uses a 68-pin VHDCI connector, while the PCI-1408 uses the 25-pin DSUB connector. Control Unit NI IMAQ PCI-1409 User Manual. The first input is sending odd rows and the second is sending even rows. Format Description: This file contains a compressed (or zipped) set of files. Jan 31, 2015 at 5:29. I have one camara Philips ccd and an acquisition plate (pci - 1409). 3. Follow the instructions on pages 1 and 2 of the Getting Started with Your IMAQ System document. Some ExpressCard adapters support USB only. National Instruments PCI-1409 Image Acquisition Module Part Number: 186914B-01, 186914F-01 . . . 4. The PCIe-8362 has two tri-color LEDs on the panel, indicating power and link status for each port. Brand: Generic. You can use the PCI-1424, PCI-1428, PCI-1422, and PXI-1422 devices with digital line-scan cameras, as well as the PCI-1409 with analog line-scan cameras. 請問PCI-1408 和PCI-1409有什麽不同? From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. For the remainder of this manual the term MXI-Express x1. $795. 5:1401–1409. When I recently installed the later Imaq driver 3. 2. Learn More About Our Mission. But, I see that there is also the PCI-1409 (at exac. 0. IMAQ PCI/PXI-1409 User Manual - National Instruments问题: 我想不打开Measurement and Automation Explorer (MAX)设置PCI-1409或PCI-1410像素深度。可以在LabVIEW中编程设置像素深度吗? 可以在LabVIEW中编程设置像素深度吗?I am a potential IMAQ rookie and spent quite some time in these ones but in vain. Although I used the same Interface name in Max and in LabView. 1, 8, 7 - Serial_Parallel_SUNIX_A00_8. The PCI-1409/PXI-1409 has high-resolution, 10-bit digitization for cameras and sensors that offer 60 dB dynamic range. i got a JAI-M10/bx model. Task(). Solved! Go to Solution. National Instruments offers the PCI-1409 (778200-01) as a direct drop-in alternative to the PCI-1408. 7. * Don't choose the autoinstall exe package. If you would like to select a different folder, click Browse. . Light was generated by the standard microscope lamp. PCI-1409 Frame Grabber. IT8892E is a single-function PCI Express to PCI bridge, which is compliant with the PCI Express Base Specification Revision 1. According to us, the image should be 720x576 according to the pal standard. We have a CCIR camera connected to the PCI-1409 IMAQ frame grabber, but the image appears stretched. We aimed to develop and validate a CT radiomics model for predicting PCI success of CTOs. 3. S13- 1409 -Rev. The nixnet package contains an API for interacting with the NI-XNET driver. How is a signal aquired using PCI 1409 (external trigger0)sent thru RTSI into PCI 1422 to triggerThe following paragraphs provide a high-level overview of the steps that must be completed in the process of creating a driver for LabVIEW Real-Time. The Camera function is not interfaced as indicated. Ananda 0 KudosGet the latest official SUNIX 1-Port Parallel Card multifunction adapter drivers for Windows 11, 10, 8. Sony XC-ST70. Installing the IMAQ Vision 1400 System 1PCISlot 2 IMAQ PCI-1408 3 Computer 4 Camera Power Supply 5 Power. The NI 1409 devices work , ! device that offers comparable or greater resolution. The NI PXI/PCI 1409 (NI 1409) is a high-accuracy monochrome image acquisition device for the PXI, PCI, or CompactPCI bus. . where/how can i get the ICD file? thanks larrybHello, I am looking for an acquisition card to process images from two RS-170 cameras. This package contains the Intel Local Management Service (LMS) and Serial-over-LAN (SOL) support for Intel Active Management Technology (AMT) for the supported desktop models and operating systems. Plug the power supply cord into a power outlet. The setup is connected to a personal computer that is equipped with National Instruments IMAQ PCI 1409 and PCI GPIB cards for image capturing and processing and for communication, respectively. As an alternative I have used a video converter box that takes the rs-170 signal and converts it to firewire. The PCI-1409 is compatible with various types of cameras, including analog line-scan cameras, monochrome cameras, variable rate pixel clock cameras, and progressive scan cameras. 0 Kudos Message 1 of 6 (3,519 Views) Reply. 集録環境の問題で1409とカメラとを接続しているBNCケーブルが画像集録中に切断される可能性があります。. Geven. $502. 11-01-2012 01:05 PM. Click the Update Driver button and follow the instructions. in physical dimensions. Solution. Open a service request. 2. How can I solve the problem? Is anyone has the installation software (PCI -6025E (DAQ) and PCI -1409. However, the bottom half of the image frame is now on top. OLE 91kHz TE -100dB The HDD- 1409 D/A has been characterized with a companion AID , ) transmultiplexer systems. Missing subVI in Actimetrics FreezeFrame2 software, PCI-1409 card, Windows 7. I have one camara Philips ccd and an acquisition plate (pci - 1409). NI-IMAQ ensures interchangeable camera support, so you need not alter existing code in order to use the PCI-1409. Recently i received the CVI 8 so i installed on the computer, and. Example shows how to control exposure and reset with the IMAQ 1409. Download. 0 and IMAQ Vision to get images produced by the following non-standard method: Our image is a photomultiplier (PMT) voltage stream that is synchronised using external HSYNC and VSYNC signals. The 525 sq. Data Acq. Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers. The Red, Green, and Blue analog signal must be attached to different channels on the PCI/PXI-1409/1410 using the IMAQ A6822 to access the 4 channels of the frame grabber board. Category: Automotive NI Products Used: GPIB-USB-B Controller, LabVIEW 7. National Instruments NI IMAQ PCI-1411 Video Frame Grabber Card (USED) $175. The PCI 1409 only has one true video input and when this accessory is used the board one input is multiplexing through four different cameras. Assemble the camera and lens. . Options. Locate the device and model that is having the issue and double-click on it to open the Properties dialog box. To this point i didn't have any problem in the programming. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Data Acq. The NI 1409 device can. 1. However, the predictive value of CT radiomics model for successful percutaneous coronary intervention (PCI) has not been studied. File Name: Serial&Parallel_SUNIX_A00_8. Find many great new & used options and get the best deals for National Instruments NI IMAQ PCI-1409 - Video Frame Grabber Card - 186914 D-01 at the best online prices at eBay! I should use old frame grabber PCI-1409 in new PC, because the old one was broken. On-chip hardware auto flow control to guarantee no data loss. DISCONTINUED BY MANUFACTURER, PC BOARD ANALOG, 4 CHANNEL . It is not clear if the message is just a log note that is no longer relevant or is a log note of a current condition. 96. 1. . Coronary computed tomography (CT) angiography imaging is useful for the preprocedural evaluation of chronic total occlusion (CTO). It is "grabbed" however as a 768x576 image! This stretc. 0 bath unit. ASUS ROG STRIX B650E-E GAMING WiFi Socket AM5 (LGA 1718) Ryzen 7000 gaming motherboard (16 + 2 power stages, DDR5, 4x M. Page 3 Singapore 2265886, Spain 91 640 0085, Sweden 08 730 49 70, Switzerland 056 200 51 51, Taiwan 02 377 1200,. import PyDAQmx as nidaq t = nidaq. I have LabVIEW 2017. IMAQ examples have code for JAI-M10 camera. $807. 2 or laterOnly such a version will be compatible with the PCI-1409 and Windows 2000. The PCI-1409/PXI-1409 also have the following features: •Unlimited acquisition window size with 16 MB of onboard memory The PCI bus is the electrical interface for both NI PCI-1409 and NI PXI-1409. 3% LaECI (Lake Erie Correctional Institution) 1,376 1,365 11 0. then i go to device manager and i select PCI Serial Port and i go to the driver location es:C:SWSetupSP74499Drivers and they update perfect the driver. The board also acquires color images of stationary objects from NTSC, PAL, and RGB cameras. We have 3 National Instruments IMAQ PCI-1409 manuals available for free PDF download: User Manual, Getting Started . , Ltd. Member 06-18-2014 03:57 PM. 你好 驅動1409卡片的步驟,可以參考 1409 user manual Chapter 2,先將卡片移除,移除之前的驅動程式 重新安裝一次驅動程式,關機再插卡,開機之後windows會自動偵測到卡片,選擇自動安裝,如果成功的話 開啟MAX之後在Device Interface下的 NI-IMAQ 下就會看到 這張1409的卡片아날로그 카메라로부터 이미지를 수집하기 위해 pci 1409을 사용하고 있습니다. The study of electromagnetic sensitivity of electronic modules is crucial for the selection of a component-level pulse current injection (PCI) waveform, which will determine whether a component-level PCI test is equivalent to a system-level pulse illumination test of the system to which the electronic module belongs. If the camera is only to be used in standard mode, use the default camera files and standard LabVIEW examples. I can only find a unit that boasts 3 frames/second at 640x480 res. 2 Gen2 USB Type-C VGA Home; Support; Driver Downloads; Driver Downloads Method 1 - Select Product Name: Method 2 - Select Product Line: Method 3 - Enter Keywords or Model Name (fuzzy match):. Page 3: Install Your Pcmcia-Fbus Card Screw the mounting bracket of the PCI-FBUS card to the back panel rail of the computer. About my software : Measurement & Automation Explorer 2. After calibration, diameters on the images were measured in Photoshop (version 5. Or where else could be the problem. The IMAQ PXI-1409 and PCI-1409 are warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by. 1. All following is not documented by NI and they are completely unable to give a coherent answer about this mode of capture. This freezing has happened on two different systems in our environment. TM-200 by Pulnix. どれも見てないのドライバを私は、 PCI - 1409ボードです。. 0_RMJ9K_ZPE. Plug-n-Play, I/O address and IRQ assigned by BIOS. Message Press Alt + 0 within the editor to access accessibility instructions, or press Alt + F10 to access the menu. You can request repair, RMA, schedule calibration, or get technical support. With reference the reply We bought IMAQ A8014 cable and tried the all as indicated. . Then on a reboot it works for the half. The input signal is connected with VIDEO 0 on the IMAQ-A6822. Search. Hello, I try to use some old equipment that was working fine back in days but wasn't use for several years. 1. Epub 2018 Jul 4. Because NI-IMAQ ensures interchangeable camera support, it is not necessary to alter existing code in order to use the PCI-1409. Do Not Sell or Share My Personal Information →. /2. In the "Select Destination Location" window, click Next. All participants completed a survey of pain and anxiety. Return to Home Page; Toggle navigation; Solutions. 2018; 118 (8):1409–1418. 0, PXI Systems Alliance • CompactPCI PICMG 2. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. However, the optimal duration of combination oral antiplatelet therapy is unknown. 2. Since my signal is not a standard video signal, I have to generate the HSYNC,VSYNC and PCLK by myself and those triggers will be imported by IMAQ-A6822. choose Notepad from the list of programs, select the option to "Always use the selected program to open this kind of file", and open the file. Hi All, I am trying to replace some existing rs-170 monitors using a video capture card (PCI-1409). Data Acq. どれも見てないのドライバを私は、 PCI - 1409ボードです。. com today. J Am Coll Cardiol. png, but these images are jus. National Instruments PCI-1409 Image Acquisition Module. 問題: 什麼是S-Video? PXI/PCI-1409 PXI/PCI-1411 影像擷取卡有支援S-Video嗎? 解答: S-Video是一種彩色的影像訊號. 0. The NI PCI-1409 enables users to acquire images from variable-scan and line-scan devices with pixel clocks ranging from 2 MHz to 40 MHz. The NI PXI/PCI 1409 (NI 1409) is a high-accuracy m onochrome image acquisition device for the PXI, PCI, or CompactPCI bus. Follow the instructions to complete the installation. Rastreamento de pedido; Pedidos; Detalhes da conta; Em formação Alternar menu. Distributors: Part: Package: Stock: Lead Time: Min Order Qty: 1: 10: 100: 1,000: 10,000Hello. com. This warranty includes parts and labor. Install the NI Vision Acquisition Software before installing the NI PCI-1409. Find many great new & used options and get the best deals for Ni National Instruments IMAQ Pci-1409 Image Acquisition Module 16 MB 4 Channel at the best online prices at eBay! Free shipping for many products!A-1409 Datasheets. Locate the device and model that is having the issue and double-click on it to open the Properties dialog box. 00. " -- Timothy McDougal. Set the Frame timeout and Action inputs appropriately based on your intended. This warranty includes parts and labor. PCI-1409とアナログカメラを使用して画像集録を行なっています。. National Instruments will, at its option, repair or replace equipmen t that proves to be defective during the warranty period. My setup: Sony Hyper HAD camera NI-IMAQ PCI 1409 Software: LabVIEW RT 7. Get the latest official SUNIX 2-Port Serial Card multifunction adapter drivers for Windows 11, 10, 8. Complex PCI was defined as having at least 1 of the following features: 3 or more stents implanted, 3 or more lesions treated, bifurcation PCI, total stent length 60 mm or larger, left main PCI, or heavy. Connect the power supply to the camera. Python API for Traditional, Benchtop InstrumentsHi am using a PCI-1409 frame grabber with an RS-170 camera. 0. Re: Is there a camera file to enable the use of an e2V L3C95 CCD camera with a PCI-1409 device? Jas.